4P Cat 6 Shielded F/UTP 24AWG PE Outdoor Network Cable

RM480.00

Out of stock

Description

High-Performance Shielded Cable with Grounding Protection

This premium Category 6 F/UTP outdoor network cable is designed for reliable, high-speed data transmission in demanding outdoor environments. Engineered with a robust PE outer jacket for maximum UV protection, an aluminum foil shield to block electromagnetic interference (EMI), and a dedicated drain wire for grounding, this cable provides the ideal foundation for a stable 10/100/1000 Mbps Gigabit Ethernet network.

Key Features

  • Outdoor UV-Resistant PE Jacket: Built to withstand harsh weather, sunlight, and extreme outdoor elements.

  • F/UTP Shielding & Grounding: Equipped with an Aluminum (AL) Foil shield and a dedicated Copper Clad Aluminum (CCA) drain wire to eliminate crosstalk, EMI, and static buildup.

  • High-Performance Gigabit Foundation: Delivers the physical integrity and bandwidth required for consistent 10/100 Mb or 1 Gb Ethernet networks.

  • Simplified Structured Cabling: An excellent choice for long-term network infrastructure investments in outdoor or exposed environments.

Physical Structure Specification

Item Value
Conductor Material CCA (Copper Clad Aluminium)
Conductor Diameter 0.50 mm ± 0.01 mm (24AWG)
Insulation Material HDPE
Insulation Diameter 0.90 mm ± 0.03 mm
Pairing 4 Twisted Pairs
Pairing Color Code P1: Blue-White/Blue
P2: Orange-White/Orange
P3: Green-White/Green
P4: Brown-White/Brown
PET Tape 100% PET Film Wrapper
Drain Wire Diameter/Material 0.40 mm CCA
Shielding AL Foil – 100% Shielding
Jacket Material PE
Outer Diameter 6.0 mm ± 0.20 mm
Color Black

Mechanical & Environmental Performance

Test Item Specification Requirement
Tensile Strength HDPE > 16.0 MPa
PE > 10.0 MPa
Elongation at Break HDPE > 300%
PE > 350%
Min. Bending Radius During installation ≥ 8×Outer Diameter
After securing≥ 4×Outer Diameter
Temperature Range Operating & Storage Temp: -40℃ to 70℃
Installation Temp: -10℃ to 50℃
Weather Resistance The PE outer sheath offers excellent water resistance and UV resistance (suitable for outdoor installation).

Electrical Performance @ 20°C

Electrical Parameter Specification Requirement
DC Resistance ≤14.5 Ω/100m (Absolute maximum limit, based on 20°C)
DC Resistance Unbalance ≤5.0%
Characteristic Impedance 100±15Ω (1-250MHz)
Mutual Capacitance ≤5.6 nF/100m
Capacitance Unbalance ≤330pF/100m
Delay Skew ≤45ns/100m(1-250MHz)
NVP 67%-69%

High Frequency Transmission Data / 100m

MHz Attenuation

(dB/100m)≤

NEXT

(dB)≥

RL

(dB)≥

PS-NEXT

(dB)≥

1 2 74.3 20 72.3
4 3.8 65.3 23 63.3
10 6 59.3 25 57.3
16 7.6 56.2 25 54.2
31.25 10.7 51.9 23.6 49.9
62.50 15.4 47.4 21.5 45.4
100 19.8 44.3 20.1 42.3
250 32.8 38.3 17.3 36.3
DOWNLOAD PDF

Technical Data Sheet

Download